Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Chemosphere ; 355: 141809, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38548080

RESUMEN

This study presents a novel approach that integrates ozone-driven chemical oxidation to convert NO into soluble NO2, followed by the simultaneous absorption of NO2 and SO2 into a CaCO3-based slurry using the redox catalyst potassium iodide (KI). Using cyclic voltammetry, we demonstrate the redox properties of the I2/2I- couple, which facilitates NO2 reduction into soluble NO2- and catalyst regeneration through sulfite (SO32-)-driven reduction, thus establishing a closed catalytic cycle within the components of flue gas. In lab-scale wet-scrubbing tests, we explore the effect of various operational parameters (i.e., KI concentration, pH, and SO2 concentration), with a 15 h stability test demonstrating >60% NOx and >99% SO2 removal efficiency when the pH is controlled between 7.5 and 8.5. A successful pilot-scale implementation conducted at an inlet flow rate of 1000 m3 h-1 further confirmed the reproducibility of the proposed redox-catalytic cycle. Our study offers a cost-effective, sustainable, and scalable solution for effectively mitigating NOx and SO2 emissions at low temperatures.


Asunto(s)
Óxidos de Nitrógeno , Dióxido de Azufre , Óxidos de Nitrógeno/química , Dióxido de Azufre/química , Dióxido de Nitrógeno , Yoduro de Potasio , Reproducibilidad de los Resultados , Oxidación-Reducción
2.
Toxics ; 11(11)2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37999564

RESUMEN

The mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, the increase in indoor fine particulate (PM2.5) concentration because of external PM2.5 influx through the ventilation system poses a problem. Here, we analyzed the changes in indoor PM2.5 concentration, distinguishing between cases of high and low outdoor PM2.5 concentrations and considering the efficiency of the filters used in residential mechanical ventilation systems. When using filters with the minimum efficiency reporting value (MERV) of 10 in the ventilation system, the outdoor PM2.5 concentration was 5 µg/m³; compared to the initial concentration, the indoor PM2.5 concentration after 60 min decreased to 73%. When the outdoor PM2.5 concentration was 30-40 µg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration consistently dropped to 73-76%, regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass balance model, the error was confirmed to be within 5%, indicating a good fit. This allows for the prediction of indoor PM2.5 under various conditions when using mechanical ventilation systems, enabling the formulation of strategies for maintaining indoor PM2.5, as recommended by the World Health Organization.

3.
Toxics ; 11(11)2023 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-37999583

RESUMEN

The educational and play-related activities of children proceed mainly indoors in a kindergarten. High concentrations of indoor PM2.5 and CO2 have been linked to various harmful effects on children, considerably impacting their educational outcomes in kindergarten. In this study, we explore different scenarios involving the operation of mechanical ventilation systems and air purifiers in kindergartens. Using numerical models to analyze indoor CO2 and PM2.5 concentration, we aim to optimize strategies that effectively reduce these harmful pollutants. We found that the amount of ventilation required to maintain good air quality, per child, was approximately 20.4 m3/h. However, we also found that as the amount of ventilation increased, so did the concentration of indoor PM2.5; we found that this issue can be resolved using a high-grade filter (i.e., a MERV 13 grade filter with a collection efficiency of 75%). This study provides a scientific basis for reducing PM2.5 concentrations in kindergartens, while keeping CO2 levels low.

4.
Toxics ; 10(11)2022 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-36422893

RESUMEN

An in-duct two-stage electrostatic precipitator (ESP) improved by ion diffusion effect was studied. We increased the collection efficiency of a two-stage electrostatic precipitator without additional energy input by adjusting the space arrangement of the charger and the collector, which increased the particle diffusion charging time. The collection efficiency and the particle charge were systematically investigated according to the occurrence of diffusion charging and electric field charging in the charger as generated by the negative ions. The collection efficiency of the separated two-stage ESP was 39% higher, on average, than the theoretical efficiency at the same power consumption. Through simulation, it was verified that the ions generated in the carbon fiber ionizer penetrated the charger. We proposed a modified charging mechanism assuming that the penetrated ions cause additional particle charge. The optimal separation distance between the charger and the collector, which showed the maximum collection efficiency, was derived through the modified charging model. Therefore, the in-duct two-stage ESP developed in this study is a promising energy-efficient and cost-saving design for indoor air management.

5.
Indoor Air ; 32(11): e13173, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36437657

RESUMEN

Indoor PM2.5 in apartments must be effectively managed to minimize adverse impacts on human health. Cooking is the one of the main PM2.5 sources in apartments, and indoor air quality (IAQ) management methods (natural ventilation, mechanical ventilations, range hoods, and air purifiers) are typically used to reduce PM2.5 generated during cooking. For effective control of indoor PM2.5 , prediction of PM2.5 reduction for various IAQ management methods is necessary. This study carefully predicted indoor PM2.5 concentrations in an apartment when IAQ management methods were applied separately and/or in combination during cooking. The infiltration and exfiltration were verified by comparing the experimental results of CO2 concentration with those predicted with or without mechanical ventilation. The deposition rate for PM2.5 generated by cooking was also derived by comparing the experimental PM2.5 changes with the predicted values for PM2.5 natural decay. Through this method, effective PM2.5 control ways during cooking in apartments can be proposed, such as natural ventilation with a range hood for 30 min and then the operation of an air purifier for 30 min. Additionally, if this prediction is combined with energy consumption, it will be possible to propose the most energy-efficient indoor PM2.5 control methods for various seasons and outdoor conditions.


Asunto(s)
Contaminación del Aire Interior , Humanos , Contaminación del Aire Interior/análisis , Culinaria , Material Particulado/análisis , República de Corea
6.
Toxics ; 10(10)2022 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-36287881

RESUMEN

Particulate matter, including airborne pathogens, is of particular concern because it can cause the spread of diseases through aerosol transmission. In this study, a new concept is proposed: on-demand antiviral electrostatic precipitators (ESPs) with electrothermal-based antiviral surfaces. We applied electrothermal-based antiviral surfaces to air-purifying applications and demonstrated that the proposed method is effective with regard to collecting airborne virus particles on collection plates in a two-stage ESP. With alternating current power, MS2 bacteriophage and H1N1 viruses were completely deactivated after exposure to 50 °C for 30 min. This remarkable antiviral performance via electrothermal effects indicates that on-demand platforms for self-antiviral surfaces can perform sterilization immediately without generating secondary pollutants, thus effectively preventing the spread of infectious microorganisms in public places. We believe that the results of this study can provide useful guidelines for the design and realization of practical and wearable devices for antiviral air-purifying applications.

7.
Toxics ; 10(10)2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36287889

RESUMEN

Indoor PM2.5 must be effectively controlled to minimize adverse impacts on public health. Cooking is one of the main sources of PM2.5 in residential areas, and indoor air quality (IAQ) management methods such as natural and mechanical ventilation, range hood, and air purifier are typically used to reduce cooking-generated PM2.5 concentrations. However, studies on the combined effects of various IAQ management methods on indoor PM2.5 reduction and energy consumption are limited. In this study, a theoretical model was established to estimate the performance of various IAQ management methods for controlling indoor PM2.5 concentrations and energy consumption. The model was verified by comparative experiments in which, various IAQ management methods were operated individually or combined. Seasonal energy consumption was calculated through the verified model, and energy consumption saving scenarios were derived for maintaining indoor PM2.5 concentrations less than 10 µg/m3, a World Health Organization annual guideline, under fair and poor outdoor PM2.5 concentrations of 15 and 50 µg/m3, respectively. Based on our results, we found that energy consumption could be reduced significantly by applying natural ventilation in spring, autumn, and summer and mechanical ventilation in winter. Our study identified efficient energy saving PM2.5 management scenarios using various IAQ management methods by predicting indoor PM2.5 concentration and energy consumption according to the annual life patterns of typical residents in South Korea.

8.
Toxics ; 10(10)2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-36287896

RESUMEN

It is important to control airborne particles in residential houses for protecting human health. Indoor particulate matter of <2.5 µm (PM2.5) can be effectively monitored and managed using an air purifier. In this study, the actual clean air delivery rates in residential houses (CADRActual) were acquired by comparing decay rates of fine particles with and without operations of the air purifier under actual conditions, following the standard CADR of an air purifier obtained in a closed test chamber. The measurements of CADRActual at different outdoor PM2.5 concentrations over a month in two residential houses revealed different airtightness levels, compared to the standardized clean air delivery rate of the air purifier (CADRAP). Air changes per hour at 50 Pa (ACH50) was 4.8 h−1 for "house A" (built in 2007) and 2.1 h−1 for "house B" (built in 2018). The CADR of the air purifier used in this study was 10.6 m3/min, while the averaged CADRActual at the "house A" was 7.2 m3/min (approximately 66% of the CADR of the air purifier) and 9.5 m3/min at "house B" (approximately 90% of the CADR of the air purifier). Under the outdoor PM2.5 concentrations of <35 µg/m3, the averaged CADRActual of house A and house B were 7.8 ± 0.3 and 9.7 ± 0.4 m3/min, respectively. However, under the outdoor PM2.5 concentrations of >35 µg/m3, the analogous averaged concentrations were 6.8 ± 0.6 and 9.6 ± 0.3 m3/min for houses A and B, respectively. The measured CADRActual agreed well with the theoretical estimates of CADRActual acquired by the mass balance equation using the infiltration rate of ACH50/20. We also estimated CADRActual/CADRAP for house C built in 2017, where the ACH50 was 1.8 h−1. Overall, this study demonstrated how CADRActual/CADRAP of an air purifier at residential houses can be predicted according to outdoor PM2.5 concentration and airtightness of the house. As shown, it can be closer to 1 at lower ACH50 houses and at lower outdoor PM2.5 concentrations.

9.
Chem Eng J ; 440: 135830, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35313452

RESUMEN

Outbreaks of airborne pathogens pose a major threat to public health. Here we present a single-step nanocoating process to endow commercial face mask filters with photobiocidal activity, triboelectric filtration capability, and washability. These functions were successfully achieved with a composite nanolayer of silica-alumina (Si-Al) sol-gel, crystal violet (CV) photosensitizer, and hydrophobic electronegative molecules of 1H, 1H, 2H, 2H-perfluorooctyltriethoxysilane (PFOTES). The transparent Si-Al matrix strongly immobilized the photosensitizer molecules while dispersing them spatially, thus suppressing self-quenching. During nanolayer formation, PFOTES was anisotropically rearranged on the Si-Al matrix, promoting moisture resistance and triboelectric charging of the Si-Al/PFOTES-CV (SAPC)-coated filter. The SAPC nanolayer stabilized the photoexcited state of the photosensitizer and promoted redox reaction. Compared to pure-photosensitizer-coated filters, the SAPC filter showed substantially higher photobiocidal efficiency (∼99.99 % for bacteria and a virus) and photodurability (∼83 % reduction in bactericidal efficiency for the pure-photosensitizer filter but ∼0.34 % for the SAPC filter after 72 h of light irradiation). Moreover, after five washes with detergent, the SAPC filter maintained its photobiocidal and filtration performance, proving its reusability potential. Therefore, this SAPC nanolayer coating provides a practical strategy for manufacturing an antimicrobial and reusable mask filter for use during the ongoing COVID-19 pandemic.

10.
Artículo en Inglés | MEDLINE | ID: mdl-34444175

RESUMEN

The present study was performed to quantitatively evaluate the effects of air purifiers on the spread of COVID-19 and to suggest guidelines for their safe use. To simulate respiratory droplet nuclei and nano-sized virus aggregates, deionized water containing 100 nm of polystyrene latex (PSL) particles was sprayed using a vibrating mesh nebulizer, and the changes in the particle number concentration were measured for various locations of the particle source and air purifier in a standard 30 m3 test chamber. The spread of the simulated respiratory droplet nuclei by the air purifier was not significant, but the nano-sized aggregates were significantly affected by the airflow generated by the air purifier. However, due to the removal of the airborne particles by the HEPA filter contained in the air purifier, continuous operation of the air purifier reduced the number concentration of both the simulated respiratory droplet nuclei and nano-sized aggregates in comparison to the experiment without operation of the air purifier. The effect of the airflow generated by the air purifier on the spread of simulated respiratory droplet nuclei and nano-sized aggregates was negligible when the distance between the air purifier and the nebulizer exceeded 1 m.


Asunto(s)
Filtros de Aire , SARS-CoV-2/aislamiento & purificación , Virus , Microbiología del Aire , COVID-19/prevención & control , Humanos , Virus/aislamiento & purificación
11.
J Air Waste Manag Assoc ; 62(8): 905-15, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22916438

RESUMEN

To remove particles in corrosive gases generated by semiconductor industries, we have developed a novel non-metallic, two-stage electrostatic precipitator (ESP). Carbon brush electrodes and grounded carbon fiber-reinforced polymer (CFRP) form the ionization stage, and polyvinyl chloride collection plates are used in the collection stage of the ESP The collection performance of the ESP downstream of a wet scrubber was evaluated with KC1, silica, and mist particles (0.01-10 pm), changing design and operation parameters such as the ESP length, voltage, and flow rate. A long-term and regeneration performance (12-hr) test was conducted at the maximum operation conditions of the scrubber and ESP and the performance was then demonstrated for 1 month with exhaust gases from wet scrubbers at the rooftop of a semiconductor manufacturing plant in Korea. The results showed that the electrical and collection performance of the ESP (16 channels, 400x400 mm2) was maintained with different grounded plate materials (stainless steel and CFRP) and different lengths of the ionization stage. The collection efficiency of the ESP at high air velocity was enhanced with increases in applied voltages and collection plate lengths. The ESP (16 channels with 100 mm length, 400x400 mm2x540 mm with a 10-mm gap) removed more than 90% of silica and mistparticles with 10 and 12 kV applied to the ESPat the air velocity of 2 m/s and liquid-to-gas ratio of 3.6 L/m3. Decreased performance after 13 hours ofcontinuous operation was recovered to the initial performance level by 5 min of water washing. Moreover during the 1-month operation at the demonstration site, the ESP showed average collection efficiencies of 97% based on particle number and 92% based on total particle mass, which were achieved with a much smaller specific corona power of 0.28 W/m3/hr compared with conventional ESPs.


Asunto(s)
Contaminantes Atmosféricos/química , Contaminación del Aire/prevención & control , Gases/química , Material Particulado/química , Semiconductores , Precipitación Química , Residuos Industriales , Electricidad Estática
12.
J Air Waste Manag Assoc ; 61(12): 1334-43, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22263421

RESUMEN

A novel two-stage wet electrostatic precipitator (ESP) has been developed using a carbon brush pre-charger and collection plates with a thin water film. The electrical and particle collection performance was evaluated for submicrometer particles smaller than 0.01- 0.5 micrometer in diameter by varying the voltages applied to the pre-charger and collection plates as well as the polarity of the voltage. The collection efficiency was compared with that calculated by the theoretical models. The long-term performances of the ESP with and without water films were also compared in tests using Japanese Industrial Standards dust. The experimental results show that the carbon brush pre-charger of the two-stage wet ESP had approximately 10% particle capture, while producing ozone concentrations of less than 30 ppb. The produced amounts of ozone are significantly lower than the current limits set by international agencies. The ESP also achieved a high collection rate performance, averaging 90% for ultrafine particles, as based on the particle number concentration at an average velocity of 1 m/sec corresponding to a residence time of 0.17 sec. Higher particle collection efficiency for the ESP can be achieved by increasing the voltages applied to the pre-charger and the collection plates. The decreased collection efficiency that occurred during dust loading without water films was completely avoided by forming a thin water film on the collection plates at a water flow rate of 6.5 L/min/m(2).


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire/prevención & control , Precipitación Química , Ozono/análisis , Material Particulado/análisis , Filtración , Humanos , Electricidad Estática
13.
Sci Total Environ ; 408(21): 5158-64, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-20692021

RESUMEN

The collection of particles in CO(2)-enriched environments has long been important for the capture of CO(2) in order to clean gases via oxy-fuel combustion. We here report on the collection characteristics of fine and ultrafine particles using an electrostatic precipitator (ESP) in a CO(2)-enriched atmosphere. In order to understand the characteristics of particle collection in CO(2)-rich gas mixtures, the ionic properties of a CO(2)-enriched atmosphere was also investigated. The electrical mobility of the ions in a CO(2)-enriched atmosphere was found to be about 0.56 times that found in a conventional air atmosphere, due to the higher mass of CO(2) gas compared to that of air. The low electrical mobility of ions resulted in a low corona current under CO(2)-enriched conditions. The collection efficiency of particles in a CO(2)-rich atmosphere for a given power consumption was thus somewhat lower than that found in air, due to the low quantity of particle charging in CO(2)-enriched air. At the same time, higher temperatures led to the higher electrical mobility of ions, which resulted in a greater collection efficiency for a given power. The presence of a negative corona also led to a greater collection efficiency of particles in an ESP than that achieved for a positive corona.


Asunto(s)
Contaminantes Atmosféricos/química , Dióxido de Carbono/química , Restauración y Remediación Ambiental/instrumentación , Material Particulado/química , Electricidad Estática , Contaminantes Atmosféricos/análisis , Restauración y Remediación Ambiental/métodos , Iones/química , Oxígeno/análisis , Oxígeno/química , Material Particulado/análisis , Temperatura
14.
Nat Nanotechnol ; 1(2): 117-21, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18654162

RESUMEN

The development of nanodevices that exploit the unique properties of nanoparticles will require high-speed methods for patterning surfaces with nanoparticles over large areas and with high resolution. Moreover, the technique will need to work with both conducting and non-conducting surfaces. Here we report an ion-induced parallel-focusing approach that satisfies all requirements. Charged monodisperse aerosol nanoparticles are deposited onto a surface patterned with a photoresist while ions of the same polarity are introduced into the deposition chamber in the presence of an applied electric field. The ions accumulate on the photoresist, modifying the applied field to produce nanoscopic electrostatic lenses that focus the nanoparticles onto the exposed parts of the surface. We have demonstrated that the technique could produce high-resolution patterns at high speed on both conducting (p-type silicon) and non-conducting (silica) surfaces. Moreover, the feature sizes in the nanoparticle patterns were significantly smaller than those in the original photoresist pattern.


Asunto(s)
Aerosoles/química , Cristalización/métodos , Nanoestructuras/química , Nanoestructuras/ultraestructura , Nanotecnología/métodos , Campos Electromagnéticos , Sustancias Macromoleculares/química , Ensayo de Materiales , Conformación Molecular , Tamaño de la Partícula , Propiedades de Superficie
15.
J Colloid Interface Sci ; 287(1): 135-40, 2005 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15914157

RESUMEN

Patterned deposition of nanoparticles is a prerequisite for the application of unique properties of nanoparticles in future nanodevices. Recent development of nanoxerography requires highly charged aerosol nanoparticles to avoid noise deposition due to random Brownian motion. However, it has been known that it is difficult to charge aerosol nanoparticles with more than two elementary charges. The goal of this work is to develop a simple technique for obtaining highly charged monodisperse aerosol nanoparticles by means of electrospray of colloidal suspension. Highly charged aerosol nanoparticles were produced by electrospraying (ES) and drying colloidal suspensions of monodisperse gold nanoparticles. Size and charge distributions of the resultant particles were measured. We demonstrate that this method successfully charges monodisperse nanoparticles very highly, e.g., 122 elementary charges for 25.0 nm, 23.5 for 10.5 nm, and 4.6 for 4.2 nm. The method described here constitutes a convenient, reliable, and continuous tool for preparing highly charged aerosol nanoparticles from suspensions of nanoparticles produced by either wet chemistry or gas-phase methods.

16.
Anal Sci ; 19(6): 843-51, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12834222

RESUMEN

Cluster ions and residue nanoparticles with sizes below 30 nm were generated by electrospraying (ES) and drying droplets of pure water, tap water, and aqueous solutions of salts. The mobility spectra of the cluster ions between 9.1 and 9.3 x 10(-5) m2/(V s) were measured using a differential mobility analyzer (DMA) operated at room temperature and atmospheric pressure. A modified Faraday cup and a condensation nucleus counter were used for detection. The concentrations of total residue/contaminants in the water were determined as a function of sizes of measured aerosol particles and of the initial droplets. Method detection limits were at sub-ppb level for pure water and sub-ppm level for tap water. ES/DMA is capable of simultaneously measuring the mobility distribution of cluster ions and concentration of total residue present in water samples.

SELECCIÓN DE REFERENCIAS